Parametry
|
| Instalace do Racku | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
| Rozměry (š x h x v) | 44.2 x 38.9 x 22.23 cm |
| Hmotnost | 9400 g |
| Správa platformy | ProCurve Manager (included); ProCurve Manager Plus;\ncommand line interface; Web browser; configuration menu; out-of--band management (serial RS-232C) |
| Zadní konektory | 8 open module slots; Supports a maximum of 192 10/100 ports or 160 Gigabit ports and 16 mini-GBICs, or a combination; 1 RS-232C DB-9 console port\n8 open module slots; Supports a maximum of 192 10/100 ports or 160 Gigabit ports and 16 mini-GBICs, or a combination |
| Spotřeba elektrické energie | 630 W |
| Požadavek výkonu | 100–127 VAC/200–240 VAC; 50/60 Hz |
| Tepelné vyzařování | 2,152 BTU/h |
| Dostupnost napájení | 8.2/3.8 A |
| Splňujě průmyslové standardy | EN 55024/CISPR-24; ESD: IEC 61000-4-2, 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3, 3V/m; EFT/Burst: IEC 61000-4-4, 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5, 1 kV/2 kV AC; Conducted: IEC 61000-4-6, 3V; Power frequency magnetic field: IEC 61000-4-8, 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11, >95% reduction, 0.5 period, 30% reduction, 25 periods; Harmonics: EN 61000-3-2/IEC 61000-3-2; Flicker: EN 61000-3-3/IEC 61000-3-3 |
| Bezpečnost | cUL (CSA 950); EN 60950/IEC 950; NOM-019-SCFI-1994; UL 1950 3rd edition |
| Elektromagnetické vyzařování | FCC Class A; EN 55022/CISPR-22 Class A; VCCI Class A |
| Doporučená provozní vlhkost | 15-95 % |
| Provozní nadmořská výška | 4,500 m |
| Provozní rozsah teplot | 0 - 55 °C |
| Rozsah teprot při skladování (T-T) | -40-70 °C |
| Skladovací vlhkost | 15-95 % |
| Paměť a procesor | Fabric: Motorola PowerPC @ 200 MHz, 8 MB flash, 32 MB SDRAM; Module: IDT MIPS32 @ 125 MHz, 512 KB flash, 512 KB SRAM; Packet buffer size: 1 MB |
| Podporované síťové protokoly | RFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 Simple Network Time Protocol; IEEE 802.3X Flow Control; DHCP Relay; RFC 2236 IGMPv1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol; Cisco Fast EtherChannel® (FEC); RFC 1492 TACACS+; RFC 2138 RADIUS; RFC 2866 RADIUS accounting; SSHv1/SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; IEEE 802.1Q VLAN tagging; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm), and 9 (events); RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and 802.1Q Bridge MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB |
| Odezva | <10.2 µs (FIFO 64-byte packets) |
| Switching capacity | 36.6 Gbps |
| Velikost tabulky adres | 8,000 entries |
| Technické vlastnosti | 802.3ad Link Aggregation Control Protocol (LACP) and HP trunking802.3ad Link Aggregation Control Protocol (LACP) and HP trunking: support up to 6 trunks, each with up to 4 links (ports) per trunk; trunking across modules is supported\nHot-swappable modulesHot-swappable modules: permit modules and mini-GBICs to be added or swapped without interrupting the network\nFast switch fabricFast switch fabric: high-performance switch fabric (up to 36.6 Gbps)\nPort securityPort security: prevents unauthorised access using MAC address lockdown\nTraffic prioritization (802.1p)Traffic prioritization (802.1p): allows real-time traffic classification into 8 priority levels mapped to 3 queues\nDual flash imagesDual flash images: provide independent primary and secondary OS files for backup while upgrading\nVLAN support and taggingVLAN support and tagging: support complete 802.1Q (4,096 VLAN IDs) and 256 VLANs simultaneously\nOptional redundant power supplyOptional redundant power supply: provides uninterrupted power\nBasic IP routingBasic IP routing: enables automatic routing with up to 16 external routes - including one default route - in IP networks\nFast Path TechnologyFast Path Technology: wire-speed switching of intramodule traffic for up to 71.4 million pps throughput |
| Funkcje zarządzania | ProCurve Manager (included); ProCurve Manager Plus;\ncommand line interface; Web browser; configuration menu; out-of--band management (serial RS-232C) |
| Inne połączenia | 8 open module slots; Supports a maximum of 192 10/100 ports or 160 Gigabit ports and 16 mini-GBICs, or a combination\n8 open module slots; Supports a maximum of 192 10/100 ports or 160 Gigabit ports and 16 mini-GBICs, or a combination; 1 RS-232C DB-9 console port |
| Pamięć i procesor | Fabric: Motorola PowerPC @ 200 MHz, 8 MB flash, 32 MB SDRAM; Module: IDT MIPS32 @ 125 MHz, 512 KB flash, 512 KB SRAM; Packet buffer size: 1 MB |
| Obsługiwane protokoły sieciowe | RFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 Simple Network Time Protocol; IEEE 802.3X Flow Control; DHCP Relay; RFC 2236 IGMPv1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol; Cisco Fast EtherChannel® (FEC); RFC 1492 TACACS+; RFC 2138 RADIUS; RFC 2866 RADIUS accounting; SSHv1/SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; IEEE 802.1Q VLAN tagging; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm), and 9 (events); RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and 802.1Q Bridge MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB |
| Opóźnienie | <10.2 µs (FIFO 64-byte packets) |
| Przepustowość rutowania/przełączania | 36.6 Gbps |
| Przepustowość | up to 71.4 mpps |
| Wielkość tabeli adresów | 8,000 entries |
| Funkcje techniczne | Fast switch fabricFast switch fabric: high-performance switch fabric (up to 36.6 Gbps)\nBasic IP routingBasic IP routing: enables automatic routing with up to 16 external routes - including one default route - in IP networks\nVLAN support and taggingVLAN support and tagging: support complete 802.1Q (4,096 VLAN IDs) and 256 VLANs simultaneously\nPort securityPort security: prevents unauthorised access using MAC address lockdown\nFast Path TechnologyFast Path Technology: wire-speed switching of intramodule traffic for up to 71.4 million pps throughput\nOptional redundant power supplyOptional redundant power supply: provides uninterrupted power\nHot-swappable modulesHot-swappable modules: permit modules and mini-GBICs to be added or swapped without interrupting the network\nDual flash imagesDual flash images: provide independent primary and secondary OS files for backup while upgrading\n802.3ad Link Aggregation Control Protocol (LACP) and HP trunking802.3ad Link Aggregation Control Protocol (LACP) and HP trunking: support up to 6 trunks, each with up to 4 links (ports) per trunk; trunking across modules is supported\nTraffic prioritization (802.1p)Traffic prioritization (802.1p): allows real-time traffic classification into 8 priority levels mapped to 3 queues |
| Możliwości montowania w stelażu | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
| Wymiary produktu (S x G x W) | 44.2 x 38.9 x 22.23 cm |
| Waga produktu | 9400 g |
| Zakres wilgotności względnej | 15-95 % |
| Dopuszczalna wysokość podczas eksploatacji (n.p.m.) | 4,500 m |
| Zakres temperatur (eksploatacja) | 0 - 55 °C |
| Zakres temperatur (przechowywanie) | -40-70 °C |
| Dopuszczalna wilgotność względna | 15-95 % |
| Pobór mocy | 630 W |
| Zasilanie | 100–127 VAC/200–240 VAC; 50/60 Hz |
| Emisja ciepła | 2152 BTU/godz |
| Dostępność zasilania | 8.2/3.8 A |
| Zgodny ze standradami przemysłowymi | EN 55024/CISPR-24; ESD: IEC 61000-4-2, 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3, 3V/m; EFT/Burst: IEC 61000-4-4, 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5, 1 kV/2 kV AC; Conducted: IEC 61000-4-6, 3V; Power frequency magnetic field: IEC 61000-4-8, 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11, >95% reduction, 0.5 period, 30% reduction, 25 periods; Harmonics: EN 61000-3-2/IEC 61000-3-2; Flicker: EN 61000-3-3/IEC 61000-3-3 |
| Bezpieczeństwo | cUL (CSA 950); EN 60950/IEC 950; NOM-019-SCFI-1994; UL 1950 3rd edition |
| Spełniane normy w zakresie emisji elektromagnetycznej | FCC Class A; EN 55022/CISPR-22 Class A; VCCI Class A |
| Throughput | up to 71.4 mpps |
| Safety | cUL (CSA 950); EN 60950/IEC 950; NOM-019-SCFI-1994; UL 1950 3rd edition |
| Electromagnetic emissions | FCC Class A; EN 55022/CISPR-22 Class A; VCCI Class A |
| I/O ports | 8 open module slots; Supports a maximum of 192 10/100 ports or 160 Gigabit ports and 16 mini-GBICs, or a combination\n8 open module slots; Supports a maximum of 192 10/100 ports or 160 Gigabit ports and 16 mini-GBICs, or a combination; 1 RS-232C DB-9 console port |
| Latency | <10.2 µs (FIFO 64-byte packets) |
| Switching capacity | 36.6 Gbps |
| Power consumption | 630 W |
| Power requirements | 100–127 VAC/200–240 VAC; 50/60 Hz |
| Heat dissipation | 2,152 BTU/h |
| Power availability | 8.2/3.8 A |
| Operating relative humidity range | 15-95 % |
| Operating temperature range (T-T) | 0 - 55 °C |
| Storage temperature range (T-T) | -40-70 °C |
| Storage relative humidity range | 15-95 % |
| Operating altitude | 4,500 m |
| Management platform | ProCurve Manager (included); ProCurve Manager Plus;\ncommand line interface; Web browser; configuration menu; out-of--band management (serial RS-232C) |
| MAC address table | 8,000 entries |
| Networking standards | EN 55024/CISPR-24; ESD: IEC 61000-4-2, 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3, 3V/m; EFT/Burst: IEC 61000-4-4, 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5, 1 kV/2 kV AC; Conducted: IEC 61000-4-6, 3V; Power frequency magnetic field: IEC 61000-4-8, 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11, >95% reduction, 0.5 period, 30% reduction, 25 periods; Harmonics: EN 61000-3-2/IEC 61000-3-2; Flicker: EN 61000-3-3/IEC 61000-3-3 |
| Memory and processor | Fabric: Motorola PowerPC @ 200 MHz, 8 MB flash, 32 MB SDRAM; Module: IDT MIPS32 @ 125 MHz, 512 KB flash, 512 KB SRAM; Packet buffer size: 1 MB |
| Supported network protocols | RFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 Simple Network Time Protocol; IEEE 802.3X Flow Control; DHCP Relay; RFC 2236 IGMPv1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol; Cisco Fast EtherChannel® (FEC); RFC 1492 TACACS+; RFC 2138 RADIUS; RFC 2866 RADIUS accounting; SSHv1/SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; IEEE 802.1Q VLAN tagging; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm), and 9 (events); RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and 802.1Q Bridge MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB |
| Technical features | Fast switch fabricFast switch fabric: high-performance switch fabric (up to 36.6 Gbps)\nBasic IP routingBasic IP routing: enables automatic routing with up to 16 external routes - including one default route - in IP networks\nVLAN support and taggingVLAN support and tagging: support complete 802.1Q (4,096 VLAN IDs) and 256 VLANs simultaneously\nPort securityPort security: prevents unauthorised access using MAC address lockdown\nFast Path TechnologyFast Path Technology: wire-speed switching of intramodule traffic for up to 71.4 million pps throughput\nOptional redundant power supplyOptional redundant power supply: provides uninterrupted power\nHot-swappable modulesHot-swappable modules: permit modules and mini-GBICs to be added or swapped without interrupting the network\nDual flash imagesDual flash images: provide independent primary and secondary OS files for backup while upgrading\n802.3ad Link Aggregation Control Protocol (LACP) and HP trunking802.3ad Link Aggregation Control Protocol (LACP) and HP trunking: support up to 6 trunks, each with up to 4 links (ports) per trunk; trunking across modules is supported\nTraffic prioritization (802.1p)Traffic prioritization (802.1p): allows real-time traffic classification into 8 priority levels mapped to 3 queues |
| Rack mounting | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
| Dimensions W x D x H | 44.2 x 38.9 x 22.23 cm |
| Weight | 9400 g |
|
|
|